For the FAA A&P Airframe test, aircraft hydraulic and pneumatic systems is chapter 12 of FAA-H-8083-31B, Hydraulic & Pneumatic Power Systems. Its ACS subject area, Hydraulic and Pneumatic Systems, is 5 to 10% of the test, or 5 to 10 of its 100 scored questions. Our question bank holds 280 questions on it, and the 10 below were written for this page.

Test shares and most-missed codes read from the FAA on 15 November 2026.

01 WHAT IT COVERSFAA-H-8083-31B · CH. 12

What FAA-H-8083-31B chapter 12 covers

Chapter 12 covers hydraulic fluids and why they must not be mixed, contamination and filtering, and the parts of a system: reservoirs, pumps (hand, constant displacement and variable displacement), the valves (selector, check, relief, pressure regulating, sequence, priority and shuttle), accumulators, actuators and seals.

It shows how a small aircraft system and a large transport system are laid out, with backups such as the power transfer unit and the ram air turbine, and it closes with pneumatic power systems.

It runs from pages 12-1 to 12-52 of the Aviation Maintenance Technician Handbook: Airframe, which the FAA publishes free as a PDF.

02 SHARE OF THE TESTFAA-G-ACS-1 · BLUEPRINT

How much of the FAA A&P Airframe test it is

  • 5 to 10%OF THE TESTACS area AM.II.F
  • 5 to 10QUESTIONSof 100 scored
  • 280IN OUR BANKquestions on this subject

The FAA’s Companion Guide to the ACS gives every subject area a range, not a count. Hydraulic and Pneumatic Systems (AM.II.F) is 5 to 10% (5 to 10 questions) on the 100-question Airframe test. The 15 ranges for the Airframe test add up to anywhere from 75% to 160%, so they say how big an area can get, not how many questions you will see from it.

No code in this area is on the FAA’s latest list of most-missed codes (2nd Quarter, CY25), which names a code only when it was missed more than 70% of the time on at least 100 tests.

03 EXAMPLE QUESTIONSWRITTEN FOR THIS PAGE

Aircraft hydraulic and pneumatic systems questions and answers

10 questions in the test’s own format, each with 3 options and 1 correct answer. Pick yours, then open it to see the answer and the reason. Each one names the page it was written from, so you can check it.

  1. Q.01

    A hydraulic liquid that is breaking down in service has begun to form small amounts of sludge. What usually happens to the rate at which more forms?

    FAA-H-8083-31B, ch. 12, p. 12-2

    1. AIt generally increases more and more rapidly
    2. BIt slows, because the first sludge settles out in the reservoir
    3. CIt holds steady until the system filters are changed
    SHOW THE ANSWER

    THE ANSWER IS A.

    It generally increases more and more rapidly

    Air, water, heat, constant motion and some metals can start a hydraulic liquid breaking down into sludge, gums and carbon deposits. Once small amounts have formed, the rate of formation generally speeds up, and the deposits go on to clog openings, make valves and pistons stick or leak, and give poor lubrication. The first sludge does not settle out harmlessly, and a filter change does not hold the rate steady.

  2. Q.02

    Why does an axial piston hydraulic pump deliver a practically nonpulsating output?

    FAA-H-8083-31B, ch. 12, p. 12-18

    1. AA small accumulator built into its case smooths out every stroke
    2. BIts relief valve bleeds off the peak of each pressure pulse
    3. CThe strokes of its pistons overlap, so some are always delivering
    SHOW THE ANSWER

    THE ANSWER IS C.

    The strokes of its pistons overlap, so some are always delivering

    In an axial piston pump, at any moment some pistons are moving to draw fluid in over the inlet port while others are moving to push fluid out over the outlet port. That continuous, rapid and overlapping action gives a practically nonpulsating output. No accumulator is built into the pump to do this, and a relief valve is there to limit pressure, not to smooth the flow.

  3. Q.03

    How does a typical inline check valve show which way fluid is allowed to flow through it?

    FAA-H-8083-31B, ch. 12, p. 12-24

    1. ABy a color band painted around its inlet end
    2. BBy an arrow on the outside of the housing
    3. CBy a larger thread size on its outlet port
    SHOW THE ANSWER

    THE ANSWER IS B.

    By an arrow on the outside of the housing

    A typical check valve is a spring-loaded ball and seat inside a housing. The spring compresses to let fluid through in the designed direction, and when flow stops it pushes the ball back on its seat so nothing comes back the other way. An arrow on the outside of the housing shows the direction in which flow is permitted, so the valve goes in with the arrow pointing the way the fluid should travel. A color band or a different thread is not what marks its direction.

  4. Q.04

    After a heat exchanger fault, a hydraulic system ran for some time above its specified maximum temperature. Once the fault is fixed, what does the handbook call for?

    FAA-H-8083-31B, ch. 12, p. 12-3

    1. ANothing more, since the fluid recovers once it cools back into limits
    2. BTopping up with a different fluid type to restore lost viscosity
    3. CA check of the system for contamination
    SHOW THE ANSWER

    THE ANSWER IS C.

    A check of the system for contamination

    Whenever a hydraulic system is suspected of contamination, or has been run at temperatures above its specified maximum, a check of the system is made. Heat speeds the chemical breakdown of the liquid, and liquid that looks clean can still be unfit for use. A system is serviced only with the fluid it is designed for, so adding a different type would only make matters worse.

  5. Q.05

    A loose O-ring with a blue dot turns up in the parts drawer, out of its envelope. What should you do with it for a job on a MIL-H-5606 system?

    FAA-H-8083-31B, ch. 12, p. 12-36

    1. AUse it if it passes a 4-power magnifier check for cuts and nicks
    2. BLeave it out and use a ring from a sealed envelope with its part number
    3. CUse it, since a blue mark in the color code always means it suits MIL-H-5606
    SHOW THE ANSWER

    THE ANSWER IS B.

    Leave it out and use a ring from a sealed envelope with its part number

    Color coding on O-rings is not a reliable or complete identification. It gives no size or age, it is missing or not permanent on some rings, and a ring made for phosphate ester fluid can carry a blue dot too. The basic part number on the sealed envelope is the most reliable way to identify the compound, so a loose ring of unknown history stays out, however good it looks.

  6. Q.06

    Someone at the shop swallows a significant amount of phosphate ester hydraulic fluid. What does the handbook call for?

    FAA-H-8083-31B, ch. 12, p. 12-5

    1. ATesting as the maker directs, then hospital stomach treatment
    2. BNothing at all, since phosphate ester fluids are harmless if swallowed
    3. CA glass of water, then back to work once the taste has gone
    SHOW THE ANSWER

    THE ANSWER IS A.

    Testing as the maker directs, then hospital stomach treatment

    Swallowing any hydraulic fluid should be avoided. Small amounts do not appear to be highly hazardous, but any significant amount should be tested as the fluid manufacturer directs, followed by stomach treatment supervised in a hospital. It is not something to shrug off or simply wash down with water.

  7. Q.07

    You are reconnecting the hydraulic lines after changing an actuator. Which of these would put metal particles into the system?

    FAA-H-8083-31B, ch. 12, p. 12-4

    1. ATorquing each fitting to the value in the technical instructions
    2. BCatching spilled fluid in a container set under each joint
    3. CForcing a binding fitting nut on until its threads strip
    SHOW THE ANSWER

    THE ANSWER IS C.

    Forcing a binding fitting nut on until its threads strip

    Parts are connected with care so that no metal slivers are stripped from the threaded areas. A thread forced until it strips sheds metal into the fluid, and particles like that can damage the units they pass through if a filter does not catch them. Torquing each fitting to the technical instructions and catching spilled fluid in a container are both habits that keep contamination down, and neither one adds metal.

  8. Q.08

    Before taking an accumulator apart, you are about to make sure all of its nitrogen preload has been let out. What must you be certain of first?

    FAA-H-8083-31B, ch. 12, p. 12-31

    1. AThat the hydraulic system is pressurized to its normal operating value
    2. BWhich type of high-pressure air valve the accumulator has
    3. CThat the accumulator has warmed to normal operating temperature
    SHOW THE ANSWER

    THE ANSWER IS B.

    Which type of high-pressure air valve the accumulator has

    An accumulator holds stored gas pressure, and failing to release the preload before disassembly could seriously injure the technician. Before checking that all the air or nitrogen has been discharged, be certain which type of high-pressure air valve is fitted, so the check is made the right way for that valve. Pressurizing the hydraulic side or warming the unit does nothing to make the preload safe.

  9. Q.09

    You are taking a hydraulic fluid sample because a pump is suspected of failing, not as part of the routine schedule. What should the sample label show?

    FAA-H-8083-31B, ch. 12, p. 12-4

    1. AA note under remarks that it was taken for a suspected problem
    2. BNothing extra, since every sample is tested the same way
    3. CThe fluid's color as seen in the bottle, in place of the aircraft details
    SHOW THE ANSWER

    THE ANSWER IS A.

    A note under remarks that it was taken for a suspected problem

    The sample label says under remarks whether the sample is a routine one or is being taken because of a suspected problem, so the result can be read with that in mind. Samples are taken both on a schedule and when a malfunction may have a fluid-related cause, and the label carries the aircraft and sample details, not a guess at the color.

  10. Q.10

    An actuating cylinder has a piston area of 3 square inches, a rod of 0.8 square inch and a 10-inch stroke. Counting both chambers, how much more fluid does it hold fully extended than fully retracted?

    FAA-H-8083-31B, ch. 12, p. 12-7

    1. A22 cubic inches
    2. B8 cubic inches
    3. C30 cubic inches
    SHOW THE ANSWER

    THE ANSWER IS B.

    8 cubic inches

    Fully extended, the piston side is full and the rod side is empty: 3 times 10 is 30 cubic inches. Fully retracted, the rod side is full, but the rod takes up 0.8 square inch of it, so it holds 2.2 times 10, or 22 cubic inches. The difference is 30 minus 22, which is 8 cubic inches, the rod's area times the stroke, and it is fluid the reservoir takes back every time the cylinder retracts. 30 is the piston side alone and 22 the rod side alone.

We wrote these questions for this page from the FAA handbooks. They are not FAA test questions, and none of them comes from our question bank. Each one names the handbook page it was written from, so you can check it.

04 AND THEN THE ORAL§ 65.79

How a missed code comes back at the oral

Your test report does not show the questions you missed. It prints the ACS code for what each one tested, and a question missed in this subject prints a code that starts AM.II.F. The examiner reads those codes before your oral and practical.

The Airframe oral runs from 4 questions if your written was clean up to 34, because every code you missed adds 1 more. Airframe also carries 11 practical projects, each with 2 questions attached.

Knowledge elements are tested on the written test and the oral; Risk Management elements are tested on the oral and the practical; Skill elements are tested on the practical only. The whole process is on the oral and practical page, and there are cards to practice the spoken half with on FAA A&P oral test practice questions.

05 COMMON QUESTIONSFAQ

Questions people ask about aircraft hydraulic and pneumatic systems

Q.01

What color is MIL-H-5606 hydraulic fluid?

Red. It is a mineral based fluid made from petroleum, the oldest kind, used where the fire hazard is fairly low. Some synthetic fluids are dyed purple or green, and the phosphate ester fluids used in most transport aircraft are highly fire resistant. Different types are not mixed: even 5606 in a fire resistant fluid can take its fire resistance away.

Q.02

What does a hydraulic accumulator do?

It stores fluid under pressure, against a charge of nitrogen or air behind a diaphragm, a bladder or a piston. It damps the pressure surges that come from units operating and the pump working to hold pressure, and it helps the pump when several units operate at once.

Q.03

What is the difference between a constant and a variable displacement pump?

A constant displacement pump moves the same volume of fluid every revolution, whatever its speed, so the system needs a pressure regulator to manage its output. A variable displacement pump changes its output by itself to meet the pressure the system demands.

Q.04

What does a priority valve do?

It gives the critical systems priority over the others when system pressure is low. Above its set pressure every system gets fluid; below it, the valve shuts off the less important systems until the pressure recovers.

Q.05

How many aircraft hydraulic and pneumatic systems questions are on the FAA A&P Airframe test?

The FAA does not publish a fixed number. Its Companion Guide to the ACS gives the Hydraulic and Pneumatic Systems subject area 5 to 10% of the Airframe test, which is 5 to 10 of the 100 scored questions. That is a range, not a quota, so your own test can land anywhere inside it.

Q.06

Which FAA handbook chapter covers aircraft hydraulic and pneumatic systems?

Chapter 12 of FAA-H-8083-31B, the Aviation Maintenance Technician Handbook: Airframe, titled "Hydraulic & Pneumatic Power Systems". It runs from pages 12-1 to 12-52, and the FAA publishes the whole handbook free as a PDF.

FREE PLAN · NO CARD · 25 QUESTIONS TO START

The bank holds 280 aircraft hydraulic and pneumatic systems questions.

Start with one free set: 25 questions and 25 fill-in-the-gaps from any of our 44 subjects, which cover every ACS subject area. Each question has 3 answer choices, like the FAA A&P tests, with a written explanation behind every answer and, for every answer written from the FAA handbooks, the chapter it came from. It needs no card. Pro opens the rest of the bank, the full study guides and the timed mock papers.

Start free

Or answer a few first. The free FAA A&P practice test runs on the page, with no account.