For the FAA A&P General test, aircraft cleaning and corrosion control is chapter 8 of FAA-H-8083-30B, Cleaning & Corrosion Control. Its ACS subject area, Cleaning and Corrosion Control, is 5 to 10% of the test, or 3 to 6 of its 60 scored questions. Our question bank holds 230 questions on it, and the 10 below were written for this page.

Test shares and most-missed codes read from the FAA on 15 November 2026.

01 WHAT IT COVERSFAA-H-8083-30B · CH. 8

What FAA-H-8083-30B chapter 8 covers

Chapter 8 explains what corrosion is, what speeds it up, and the forms it takes on an aircraft: surface corrosion, filiform, pitting, intergranular and exfoliation corrosion, stress corrosion cracking, fretting, and the galvanic corrosion of dissimilar metals in contact. It names the places corrosion is most often found, from battery compartments and exhaust trail areas to wheel wells and lavatories.

It then covers removing corrosion and treating each metal, corrosion limits, metal finishing and chemical surface treatments, and protective paint finishes. The last part is cleaning: exterior, interior and powerplant cleaning, and the solvents, emulsion cleaners, soaps, abrasives and chemical cleaners used for each.

It runs from pages 8-1 to 8-29 of the Aviation Maintenance Technician Handbook: General, which the FAA publishes free as a PDF.

02 SHARE OF THE TESTFAA-G-ACS-1 · BLUEPRINT

How much of the FAA A&P General test it is

  • 5 to 10%OF THE TESTACS area AM.I.G
  • 3 to 6QUESTIONSof 60 scored
  • 230IN OUR BANKquestions on this subject

The FAA’s Companion Guide to the ACS gives every subject area a range, not a count. Cleaning and Corrosion Control (AM.I.G) is 5 to 10% (3 to 6 questions) on the 60-question General test. The 12 ranges for the General test add up to anywhere from 60% to 130%, so they say how big an area can get, not how many questions you will see from it.

The FAA’s latest report on the most-missed codes (2nd Quarter, CY25, 1 July 2024 to 30 June 2025) lists AM.I.G.K6, “Corrosion identification and inspection”, in this area, missed 78.49% of the time on the General test. That is a whole subject element across everyone who took the test, not one question, and it is the part of this subject the FAA says people get wrong most.

03 EXAMPLE QUESTIONSWRITTEN FOR THIS PAGE

Aircraft cleaning and corrosion control questions and answers

10 questions in the test’s own format, each with 3 options and 1 correct answer. Pick yours, then open it to see the answer and the reason. Each one names the page it was written from, so you can check it.

  1. Q.01

    Wormlike trails under the paint show that filiform corrosion has started on an aluminum wing skin. How can the corrosion be taken off?

    FAA-H-8083-30B, ch. 8, p. 8-6

    1. AWipe it off with a rag soaked in solvent
    2. BScrub it out with a steel wire brush
    3. CGlass bead blasting or sanding
    SHOW THE ANSWER

    THE ANSWER IS C.

    Glass bead blasting or sanding

    Filiform corrosion is removed with glass bead blasting material, using portable abrasive blasting equipment, or by sanding. The area is then treated and refinished, because filiform left in place can lead on to intergranular corrosion around fasteners and at seams. A solvent only takes off dirt and grease, not corrosion, and a steel wire brush leaves bits of steel in the aluminum that start new corrosion.

  2. Q.02

    Exfoliation is an advanced form of intergranular corrosion. On which kind of part is it most often seen?

    FAA-H-8083-30B, ch. 8, p. 8-7

    1. AOn extruded sections, such as spars, with thin grains
    2. BOn magnesium castings, where the grains are large and coarse
    3. CUnder the paint on skins with a polyurethane finish
    SHOW THE ANSWER

    THE ANSWER IS A.

    On extruded sections, such as spars, with thin grains

    Exfoliation is intergranular corrosion that has gone far enough for expanding corrosion products at the grain boundaries to lift the surface grains up. It is most often seen on extruded sections, where the grains are thinner than in rolled forms, and spars are a typical example. Thin grains are the risk, not large coarse ones, and wormlike trails under polyurethane paint are filiform corrosion, a different attack. Eddy current and ultrasonic inspection are used to find it.

  3. Q.03

    Anodizing is the most common surface treatment for unclad aluminum alloy parts. What does the process do to the metal?

    FAA-H-8083-30B, ch. 8, p. 8-22

    1. AIt rolls a thin layer of pure aluminum onto each side
    2. BIt makes the natural oxide film thicker and denser
    3. CIt plates a thin coat of cadmium over the bare alloy
    SHOW THE ANSWER

    THE ANSWER IS B.

    It makes the natural oxide film thicker and denser

    In anodizing the part is the positive pole in an electrolytic bath, often chromic acid, which builds up an aluminum oxide film. Aluminum oxide is naturally protective, and anodizing only makes that film thicker and denser. A rolled-on layer of pure aluminum is Alclad, and cadmium plating is a finish for steel hardware.

  4. Q.04

    A fitting made of 7075 aluminum turns out to have been heat treated wrongly, and it has served for years near the sea. Its surface looks clean and smooth. What does that clean surface tell you about intergranular corrosion?

    FAA-H-8083-30B, ch. 8, p. 8-7

    1. AThat there is none, since this attack always shows on the surface first
    2. BNothing for certain, since this attack can be there with no surface sign
    3. CThat there is none, since 7075 is not prone to intergranular attack
    SHOW THE ANSWER

    THE ANSWER IS B.

    Nothing for certain, since this attack can be there with no surface sign

    Intergranular corrosion runs along the grain boundaries of the alloy and may exist without any visible sign on the surface. High-strength alloys such as 2014 and 7075 are more prone to it when they were heat treated wrongly and then exposed to a corrosive environment, which is just this fitting's history. So a clean surface proves nothing, and 7075 is one of the alloys most at risk, not one that is spared.

  5. Q.05

    You put paint remover on a panel with an ordinary paintbrush. Once the job is done, can that brush be cleaned and kept for brushing on primer later?

    FAA-H-8083-30B, ch. 8, p. 8-15

    1. AYes, once it has been washed out in a solvent strong enough to clear the stripper
    2. BYes, as long as it is dried out fully so no remover is left in the bristles
    3. CNo, the remover loosens its bristles and it must not be used for anything else
    SHOW THE ANSWER

    THE ANSWER IS C.

    No, the remover loosens its bristles and it must not be used for anything else

    Any paintbrush will do to spread paint remover, but the remover attacks the binder that holds the bristles, so they come loose. Once a brush has been in paint remover it must not be used for any other job. Washing or drying it does not undo the damage, and loose bristles would end up in the next coating.

  6. Q.06

    White corrosion has formed under the insulating washers of the screws on a magnesium skin panel that cannot easily be taken off. How do you get treatment to the metal under the washers?

    FAA-H-8083-30B, ch. 8, p. 8-19

    1. ALoosen the screws enough to brush the treatment in under each washer
    2. BLeave the washers alone, since the insulation stops corrosion under them
    3. CPaint over the washers and screw heads to seal the corrosion in
    SHOW THE ANSWER

    THE ANSWER IS A.

    Loosen the screws enough to brush the treatment in under each washer

    Magnesium skin corrosion usually starts at panel edges, under washers and where the skin was drilled, sheared or damaged. If the panel comes off easily it is removed so every spot can be treated. If it does not, the screws are loosened just enough to work the treatment in under each insulating washer with a nonmetallic brush. An insulating washer does not stop corrosion that has already started under it, and paint over live corrosion only hides it while it keeps working.

  7. Q.07

    While insulating a magnesium-to-steel joint, a helper stretches the vinyl tape as he lays it over the primer, to get it smooth and tight. What is wrong with that?

    FAA-H-8083-30B, ch. 8, p. 8-20

    1. ANothing, since stretched tape seals moisture out better than loose tape
    2. BNothing, since a tight tape grips the primer and cannot shift in service
    3. CStretched tape tends to creep back, so it is laid on without stretching
    SHOW THE ANSWER

    THE ANSWER IS C.

    Stretched tape tends to creep back, so it is laid on without stretching

    Where magnesium is part of a dissimilar-metal joint, each surface gets at least 2 coats of zinc chromate or, better, epoxy primer, and then a layer of pressure-sensitive vinyl tape 0.003 inch thick. The tape is pressed on smoothly and firmly enough to keep out air bubbles and wrinkles, but it is not stretched, because stretched tape creeps back after it is laid.

  8. Q.08

    You must chemically treat corrosion on an aluminum part where some of the solution may stay trapped in a joint. Which treatment is less likely to corrode the metal if it gets trapped?

    FAA-H-8083-30B, ch. 8, p. 8-23

    1. AA chromic acid inhibitor solution, since it is the more active of the 2
    2. BSodium dichromate and chromic acid, since it is the less active mixture
    3. CEither one, since both are rinsed away in the same way afterward
    SHOW THE ANSWER

    THE ANSWER IS B.

    Sodium dichromate and chromic acid, since it is the less active mixture

    A solution of sodium dichromate and chromic acid is a less active mixture for treating aluminum than the chromic acid inhibitor, and trapped solutions of it are less likely to corrode metal surfaces. Where solution may stay in a joint, the less active mixture is the safer choice. Rinsing helps either way, but it cannot be relied on to reach what is trapped.

  9. Q.09

    A repair on a magnesium skin panel meant trimming, drilling and riveting, and the bare spots have now been touched up. What does that mean for later corrosion inspections of the panel?

    FAA-H-8083-30B, ch. 8, p. 8-13

    1. ATouchup cannot fully restore the original finish, so watch those areas closely
    2. BThe touchup restores full protection, so the panel needs no extra attention
    3. CThe rivets seal the holes from moisture, so watch the trimmed edges instead
    SHOW THE ANSWER

    THE ANSWER IS A.

    Touchup cannot fully restore the original finish, so watch those areas closely

    Magnesium skins give little trouble as long as their original surface finish and insulation are kept up. Trimming, drilling and riveting destroy some of that original surface treatment, and touchup can never completely restore it. So inspections must take in all magnesium skin, with special attention to edges, the areas around fasteners, and any cracked, chipped or missing paint.

  10. Q.10

    An avionics bay is cooled by ram air drawn in from outside the airplane. How should it be treated during a corrosion inspection?

    FAA-H-8083-30B, ch. 8, p. 8-13

    1. AAs a dry, sealed area, since electronics are kept away from moisture
    2. BAs a trouble area, since its cooling air brings the same conditions as engine vents
    3. CAs a low priority, since the air warms up before it reaches the equipment
    SHOW THE ANSWER

    THE ANSWER IS B.

    As a trouble area, since its cooling air brings the same conditions as engine vents

    Electronic and electrical compartments cooled by ram air or compressor bleed air see the same conditions as engine and accessory cooling vents and engine frontal areas, where dirt, dust and moisture come in with the air. Less air passes through them, and their design tries to keep water from forming, but they are still a trouble area that needs special attention.

We wrote these questions for this page from the FAA handbooks. They are not FAA test questions, and none of them comes from our question bank. Each one names the handbook page it was written from, so you can check it.

04 AND THEN THE ORAL§ 65.79

How a missed code comes back at the oral

Your test report does not show the questions you missed. It prints the ACS code for what each one tested, and a question missed in this subject prints a code that starts AM.I.G. The examiner reads those codes before your oral and practical.

The General oral runs from 4 questions if your written was clean up to 22, because every code you missed adds 1 more. General also carries 9 practical projects, each with 2 questions attached.

Knowledge elements are tested on the written test and the oral; Risk Management elements are tested on the oral and the practical; Skill elements are tested on the practical only. The whole process is on the oral and practical page, and there are cards to practice the spoken half with on FAA A&P oral test practice questions.

05 COMMON QUESTIONSFAQ

Questions people ask about aircraft cleaning and corrosion control

Q.01

What is exfoliation corrosion?

An advanced form of intergranular corrosion. The corrosion products build up along the grain boundaries just below the surface, and the force of their expanding lifts the surface grains of the metal. It is hard to detect in its early stages, and it is most often seen on extruded parts such as spars, where the grains are thinner than in rolled metal.

Q.02

What is galvanic corrosion?

Corrosion that happens when 2 dissimilar metals are in contact with an electrolyte, such as moisture, between them. The more active of the 2 corrodes. It is prevented by keeping the metals apart with an insulating barrier such as tape, sealant or primer.

Q.03

What is filiform corrosion?

A form of corrosion that grows under a paint film, recognized by its wormlike trails of corrosion products beneath the paint. It forms on painted steel and aluminum when the humidity is high and the surface is slightly acidic.

Q.04

Where does corrosion usually start on an aircraft?

In the places that trap moisture, heat or chemicals: battery compartments and vents, engine exhaust areas, lavatories and galleys, wheel wells and landing gear, the bilge areas under the floor, and anywhere 2 different metals meet. These are the places to look first.

Q.05

How many aircraft cleaning and corrosion control questions are on the FAA A&P General test?

The FAA does not publish a fixed number. Its Companion Guide to the ACS gives the Cleaning and Corrosion Control subject area 5 to 10% of the General test, which is 3 to 6 of the 60 scored questions. That is a range, not a quota, so your own test can land anywhere inside it.

Q.06

Which FAA handbook chapter covers aircraft cleaning and corrosion control?

Chapter 8 of FAA-H-8083-30B, the Aviation Maintenance Technician Handbook: General, titled "Cleaning & Corrosion Control". It runs from pages 8-1 to 8-29, and the FAA publishes the whole handbook free as a PDF.

FREE PLAN · NO CARD · 25 QUESTIONS TO START

The bank holds 230 aircraft cleaning and corrosion control questions.

Start with one free set: 25 questions and 25 fill-in-the-gaps from any of our 44 subjects, which cover every ACS subject area. Each question has 3 answer choices, like the FAA A&P tests, with a written explanation behind every answer and, for every answer written from the FAA handbooks, the chapter it came from. It needs no card. Pro opens the rest of the bank, the full study guides and the timed mock papers.

Start free

Or answer a few first. The free FAA A&P practice test runs on the page, with no account.